MY HOME
275
Energy management
COOLING CIRCULATION
PUMP
HEATING CIRCULATION
PUMP
HEATING
Wiring diagram for connecting the
solenoid valves of zones 2, 4, 6 and
8 to the heating actuator. To control
zones 1, 3, 5 and 7 replicate the same
connection between the solenoid
C1= fan-coil solenoid valve
C2= minimum ventilation speed
C3= average ventilation speed
C4= maximum ventilation speed
valves and the corresponding
actuator. The configuration must
be made correctly, maintaining the
correlation between the actuator
contact and the address of the zone
COOLING
Wiring diagram for connecting the
fan-coil to the actuator for zone 6
cooling.
To control the fan-coils belonging
to zones 1, 2, 3, 4, 5, 7 and 8
replicate the same connection,
CIRCULATION PUMP
Wiring diagram for connecting
the circulation pumps to the
corresponding actuator.
The pumps of the two systems,
heating and cooling, are controlled
by a single actuator.
correctly configuring the actuator
corresponding to the zone as
indicated in the configuration tables.
to be controlled. In the example
given here, zone 2 is controlled by
contact C1 configured with [ZA] = 0
and [ZB] = 2.
next >>
ZONE 8
ZONE 6
ZONE 4
ZONE 2
ZONE 6